Model: 12V36W - IP67
Specification
• Input: AC 90~240V, 0.4-0.86A
• Frequency: 47/63Hz
• Output current: 3A max
• Rated power: 36W Max
• Weight: 350g Size: 200*30*21mm
Electrical Parameters
DC Adjustable Range: ±10% Rated Voltage
Voltage Tolerance: ±5%
Line Regulation:±3%
Load Regulation: ±3%
Ripple and Noise: 150mVp-p Max.
Under nominal input voltage and nominal load, Parallel with a E-CAP 47uF and C-CAP 0.1uF at the terminal of output rail , measure by Oscilloscope with 20MHz Band width.
Setup time: 200ms.
Hold up time: 20ms Max;
Rise up time: 50ms max.
AC Inrush Current: 20A /115V; 40A/230V
MTBF: 50,000 hours at normal input condition
Leakage current:<0.5mA at 240Vac / 50 Hz
Insulation Resistance: I/P-O/P, I/P-FG, O/P-FG: 100MΩ / 500VDC
Withstand Voltage: I/P-O/P: 3KV ac ; I/P-FG: 1.5KVAC; O/P-FG: 0.5KVAC
Operation temp:-10℃~60℃
Storage temp:-10℃~60℃
Storage Humidity: 10% -75% non-condensing
Packaging & Delivery
100pcs/Carton
Carton size: 535*315*280mm
Delivery Detail:sample within 7 work days,25~35 days for bulk order
Features
• Charging mode:CC-CV(Constant Current-Constant Voltage)
• High efficiency and low power consumption
• Stabilized output and low noise
• Efficiency(at 100% load): >=90%
• Operating temperature:-20ºC ~ 45ºC
• Storage temperature:-40ºC ~ 85ºC
• Operating humidity:5%~90%RH
Safety protections
• Over Voltage protection - When the output voltage is over 150% rated voltage, the power supply will be protected, and will be auto-recovery when fault is removed or power on again.
• Over-Current protection - The output current is increased to be 135% of the rated, the power supply shall not be damaged, it can be self-recovery when the fault condition is removed.
• Over-Temp.- It will shut down and can be auto-recovery.
Environmental and Safety Standard
RoHS, CE, FCC